DYNAMIC SLI
Conventional vehicles without Start-Stop technology and with basic energy needs.
For Extra Power and Premium Performance.
You've got a highly equipped car? The VARTA® Silver Dynamic is the perfect choice for non-start-stop technology with the highest power needs. It offers supreme starting power (up to 15% higher than Blue) that will meet the toughest energy demands without compromise. Available in 11 models of varying capacity, CCA and size, the VARTA® Silver Dynamic is also recyclable and produced in an energy saving way.
-
NEWDYNAMIC SLI 563400061
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 63 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 610 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 563400061
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- D15
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 12 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 242/175/190
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- 027
-
Capacity
-
NEWDYNAMIC SLI 561400060
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 61 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 600 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 561400060
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- D21
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 12 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 242/175/175
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- 075
-
Capacity
-
NEWDYNAMIC SLI 560411054
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 60 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 540 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 560411054
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- D48
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 12 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 232/173/225
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- 014
-
Capacity
-
NEWDYNAMIC SLI 560410054
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 60 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 540 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 560410054
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- D47
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 12 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 232/173/225
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- 005
-
Capacity
-
NEWDYNAMIC SLI 560409054
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 60 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 540 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 560409054
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- D59
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 12 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 242/175/175
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- 075
-
Capacity
-
NEWDYNAMIC SLI 560408054
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 60 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 540 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 560408054
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- D24
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 12 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 242/175/190
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- 027
-
Capacity
-
NEWDYNAMIC SLI 560127054
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 60 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 540 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 560127054
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- D43
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 12 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 242/175/190
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- 078
-
Capacity
-
NEWDYNAMIC SLI 556400048
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 56 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 480 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 556400048
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- C14
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 12 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 242/175/190
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- 027
-
Capacity
-
NEWDYNAMIC SLI 554400053
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 54 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 530 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 554400053
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- C30
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 12 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 207/175/190
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- 012
-
Capacity
-
NEWDYNAMIC SLI 552401052
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 52 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 520 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 552401052
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- C6
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 12 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 207/175/175
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- 063
-
Capacity
-
NEWDYNAMIC SLI 552400047
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 52 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 470 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 552400047
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- C22
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 12 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 207/175/190
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- 012
-
Capacity
-
NEWDYNAMIC SLI 545413040
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 45 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 400 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 545413040
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- B20
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 12 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 207/175/190
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- 077
-
Capacity
-
NEWDYNAMIC SLI 545412040
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 45 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 400 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 545412040
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- B19
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 12 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 207/175/190
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- 012
-
Capacity
-
NEWDYNAMIC SLI 545158033
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 45 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 330 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 545158033
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- B34
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 12 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 238/129/227
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- 043
-
Capacity
-
NEWDYNAMIC SLI 545157033
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 45 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 330 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 545157033
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- B33
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 12 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 238/129/227
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- 155
-
Capacity
-
NEWDYNAMIC SLI 545156033
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 45 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 330 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 545156033
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- B32
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 12 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 238/129/227
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- 158
-
Capacity
-
NEWDYNAMIC SLI 545155033
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 45 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 330 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 545155033
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- B31
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 12 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 238/129/227
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- 156
-
Capacity
-
NEWDYNAMIC SLI 545079030
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 45 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 300 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 545079030
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- B24
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 12 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 219/135/225
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- 049
-
Capacity
-
NEWDYNAMIC SLI 545077030
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 45 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 300 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 545077030
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- B23
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 12 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 219/135/225
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- 048
-
Capacity
-
NEWDYNAMIC SLI 544402044
-
Capacity
The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
- 44 Ah
-
CCA
A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
- 440 A
-
ETN
The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
- 544402044
-
Short Code
This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- B18
-
Voltage
Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
- 12 V
-
Dimensions (L/W/H)
The dimensions are in millimetres (mm).
- 207/175/175
-
UK-Code
The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
- 063
-
Capacity
Trust a battery expert near you!
Got a question?
-
Since the turn of the millennium, start-stop technology has been introduced in more and more vehicle segments and models to comply with increasingly stringent emission regulations. Nowadays, there are hardly any new vehicles that are delivered without a start-stop function. In other words, the newer the vehicle, the more likely it is to feature automated engine shutoff.
If the car is equipped with a Battery Management Sensor, it has a Start-Stop system or at least a Smart-Charging System that requires advanced battery technology such as AGM or EFB
-
For a car with a start-stop system, the recommended battery types are Absorbent Glass Mat (AGM) or an Enhanced Flooded Battery (EFB) battery.
If an AGM battery is already installed in the vehicle, it must always be replaced with another AGM battery since the vehicle's Energy Management could overstress a Flooded battery which leads to shortend battery lifetime.
-
Although both AGM and EFB technologies are used for Start-Stop applications, there are some differences in the technologies' performance. While EFB is an improved flooded battery, AGM is a battery specifically designed for demanding applications and able to support any types of Start-Stop systems and even xEV.
Downgrading from an AGM to an EFB is not recommended since the vehicle's Energy Management System is designed for a certain battery performance. Upgrading from EFB to AGM on the other hand, is always possible and advised when your customer faces recurring battery issues.
Find more on AGM, EFB, xEV and more in our Knowledge section.