DYNAMIC SLI

Conventional vehicles without Start-Stop technology and with basic energy needs.

 

Experience peace of mind with the VARTA Dynamic SLI, a maintenance-free battery designed to deliver dependable performance. Built with proven technology, it offers long-lasting power and exceptional value, making it the ideal choice for conventional vehicles. ​

VARTA batteries meet all the standards of OE manufacturers.​
Engineered in Germany, VARTA batteries deliver precision performance and lasting reliability.​

 

  • NEW
    DYNAMIC SLI 560410054
    DYNAMIC SLI 560410054
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    60 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    540 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    560410054
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    D47
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    232/173/225
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    005
  • NEW
    DYNAMIC SLI 572409068
    DYNAMIC SLI 572409068
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    72 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    680 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    572409068
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    E43
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    278/175/175
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    100
  • NEW
    DYNAMIC SLI 552400047
    DYNAMIC SLI 552400047
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    52 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    470 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    552400047
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    C22
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    207/175/190
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    012
  • NEW
    DYNAMIC SLI 545155033
    DYNAMIC SLI 545155033
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    45 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    330 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    545155033
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    B31
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    238/129/227
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    156
  • NEW
    DYNAMIC SLI 563400061
    DYNAMIC SLI 563400061
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    63 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    610 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    563400061
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    D15
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    242/175/190
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    027
  • NEW
    DYNAMIC SLI 577400078
    DYNAMIC SLI 577400078
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    77 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    780 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    577400078
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    E44
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    278/175/190
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    096
  • NEW
    DYNAMIC SLI 560408054
    DYNAMIC SLI 560408054
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    60 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    540 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    560408054
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    D24
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    242/175/190
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    027
  • NEW
    DYNAMIC SLI 552401052
    DYNAMIC SLI 552401052
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    52 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    520 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    552401052
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    C6
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    207/175/175
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    063
  • NEW
    DYNAMIC SLI 561400060
    DYNAMIC SLI 561400060
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    61 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    600 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    561400060
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    D21
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    242/175/175
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    075
  • NEW
    DYNAMIC SLI 545077030
    DYNAMIC SLI 545077030
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    45 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    300 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    545077030
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    B23
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    219/135/225
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    048
  • NEW
    DYNAMIC SLI 556400048
    DYNAMIC SLI 556400048
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    56 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    480 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    556400048
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    C14
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    242/175/190
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    027
  • NEW
    DYNAMIC SLI 590122072
    DYNAMIC SLI 590122072
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    90 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    720 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    590122072
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    F6
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    353/175/190
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    017
  • NEW
    DYNAMIC SLI 560411054
    DYNAMIC SLI 560411054
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    60 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    540 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    560411054
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    D48
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    232/173/225
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    014
  • NEW
    DYNAMIC SLI 540126033
    DYNAMIC SLI 540126033
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    40 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    330 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    540126033
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    A14
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    187/127/227
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    054
  • NEW
    DYNAMIC SLI 585200080
    DYNAMIC SLI 585200080
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    85 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    800 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    585200080
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    F18
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    315/175/175
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    110
  • NEW
    DYNAMIC SLI 545079030
    DYNAMIC SLI 545079030
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    45 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    300 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    545079030
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    B24
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    219/135/225
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    049
  • NEW
    DYNAMIC SLI 595402080
    DYNAMIC SLI 595402080
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    95 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    800 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    595402080
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    G3
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    353/175/190
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    019
  • NEW
    DYNAMIC SLI 540127033
    DYNAMIC SLI 540127033
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    40 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    330 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    540127033
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    A15
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    187/127/227
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    055
  • NEW
    DYNAMIC SLI 570409064
    DYNAMIC SLI 570409064
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    70 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    640 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    570409064
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    E13
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    278/175/190
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    096
  • NEW
    DYNAMIC SLI 610402092
    DYNAMIC SLI 610402092
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    110 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    920 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    610402092
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    I1
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    393/175/190
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    020

Trust a battery expert near you!

As cars become more complex so do their battery exchanges. That's why we do not recommend you change your battery by yourself, unless you are a battery professional. Instead, reach out to one of our trusted VARTA® Partner workshops instead

Got a question?

  • Since the turn of the millennium, start-stop technology has been introduced in more and more vehicle segments and models to comply with increasingly stringent emission regulations. Nowadays, there are hardly any new vehicles that are delivered without a start-stop function. In other words, the newer the vehicle, the more likely it is to feature automated engine shutoff.

    If the car is equipped with a Battery Management Sensor, it has a Start-Stop system or at least a Smart-Charging System that requires advanced battery technology such as AGM or EFB

    Go to VARTA® Battery Finder

  • For a car with a start-stop system, the recommended battery types are Absorbent Glass Mat (AGM) or an Enhanced Flooded Battery (EFB) battery.

    If an AGM battery is already installed in the vehicle, it must always be replaced with another AGM battery since the vehicle's Energy Management could overstress a Flooded battery which leads to shortend battery lifetime.

    Read Article

  • Although both AGM and EFB technologies are used for Start-Stop applications, there are some differences in the technologies' performance. While EFB is an improved flooded battery, AGM is a battery specifically designed for demanding applications and able to support any types of Start-Stop systems and even xEV.

    Downgrading from an AGM to an EFB is not recommended since the vehicle's Energy Management System is designed for a certain battery performance. Upgrading from EFB to AGM on the other hand, is always possible and advised when your customer faces recurring battery issues.

    Find more on AGM, EFB, xEV and more in our Knowledge section.

    Go to Knowledge