• NEW
    DYNAMIC SLI 545603030
    DYNAMIC SLI 545603030
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    45 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    430 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    545603030
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    B34
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    238/129/227
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
  • SELL-OUT
    Quality as usual - now in sell-out phase.
    BLUE dynamic 562019052
    BLUE dynamic 562019052
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    62 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    540 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    562019052
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    D24
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    242/175/190
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
  • SELL-OUT
    Quality as usual - now in sell-out phase.
    BLUE dynamic 550601040
    BLUE dynamic 550601040
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    50 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    400 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    550601040
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    E20
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    261/175/220
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
  • NEW
    DYNAMIC SLI 543016037
    DYNAMIC SLI 543016037
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    43 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    370 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    543016037
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    B18
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    207/175/175
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
  • NEW
    PROMOTIVE SLI 650204086
    PROMOTIVE SLI 650204086
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    150 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    860 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    650204086
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    L2R
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    513/223/223
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
  • SELL-OUT
    Quality as usual - now in sell-out phase.
    BLUE dynamic 540602034
    BLUE dynamic 540602034
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    40 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    340 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    540602034
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    A13
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    187/127/227
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
  • NEW
    DYNAMIC SLI 580400060
    DYNAMIC SLI 580400060
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    80 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    600 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    580400060
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    G5
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    306/173/225
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
  • SELL-OUT
    Quality as usual - now in sell-out phase.
    BLUE dynamic 555059045
    BLUE dynamic 555059045
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    55 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    470 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    555059045
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    C14
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    242/175/190
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
  • NEW
    DYNAMIC AGM 595901085
    DYNAMIC AGM 595901085
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    95 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    850 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    595901085
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    G14
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    353/175/190
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
  • SELL-OUT
    Quality as usual - now in sell-out phase.
    BLUE dynamic 545600030
    BLUE dynamic 545600030
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    45 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    430 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    545600030
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    B31
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    238/129/227
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
  • SELL-OUT
    Quality as usual - now in sell-out phase.
    ProMotive SHD 740012120
    ProMotive SHD 740012120
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    240 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    1200 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    740012120
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    E10
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    518/276/242
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
  • SELL-OUT
    Quality as usual - now in sell-out phase.
    BLUE dynamic 570600055
    BLUE dynamic 570600055
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    70 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    600 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    570600055
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    E23
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    261/175/220
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
  • SELL-OUT
    Quality as usual - now in sell-out phase.
    BLUE dynamic 540601034
    BLUE dynamic 540601034
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    40 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    340 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    540601034
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    A15
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    187/127/227
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
  • SELL-OUT
    Quality as usual - now in sell-out phase.
    BLUE dynamic 570601055
    BLUE dynamic 570601055
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    70 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    600 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    570601055
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    E24
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    261/175/220
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
  • SELL-OUT
    Quality as usual - now in sell-out phase.
    BLUE dynamic EFB 565500065
    BLUE dynamic EFB 565500065
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    65 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    650 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    565500065
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    D54
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    278/175/175
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
  • PROMOTIVE EFB 690500105
    PROMOTIVE EFB 690500105
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    190 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    1050 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    690500105
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    513/223/242
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
  • NEW
    DYNAMIC AGM 560901068
    DYNAMIC AGM 560901068
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    60 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    680 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    560901068
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    D52
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    242/175/190
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
  • SELL-OUT
    Quality as usual - now in sell-out phase.
    SILVER dynamic AGM 580901080
    SILVER dynamic AGM 580901080
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    80 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    800 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    580901080
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    F21
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    315/175/190
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
  • NEW
    PROMOTIVE SLI 600035060
    PROMOTIVE SLI 600035060
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    100 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    600 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    600035060
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    H4
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    413/175/220
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
  • NEW
    DYNAMIC SLI 574013068
    DYNAMIC SLI 574013068
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    74 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    680 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    574013068
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    E12
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    278/175/190
    UK-Code
    The UK code helps professionals quickly to indetify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.

Do you work with batteries?

Explore VARTA®'s Training Academy and access exclusive e-learnings. Dedicated to battery professionals only.

Trust a battery expert near you!

As cars become more and more complex so do their battery exchanges. That's why we do not recommend you to exchange your battery by yourself unless you are a battery professional. Instead, reach out to one of our trusted VARTA® Partner workshops instead

Got a question?

  • Although both AGM and EFB technologies are used for Start-Stop applications, there are some differences in the technologies' performance. While EFB is an improved flooded battery, AGM is a battery specifically designed for demanding applications and able to support any types of Start-Stop systems and even xEV.

    Downgrading from an AGM to an EFB is not recommended since the vehicle's Energy Management System is designed for a certain battery performance. Upgrading from EFB to AGM on the other hand, is always possible and advised when your customer faces recurring battery issues.

    Find more on AGM, EFB, xEV and more in our Knowledge section.

    Go to Knowledge

  • The VARTA® Partner Portal provides partner workshops with assistance in this decision, with battery positions, battery selections and installation instructions for almost all vehicles which are in use in Europe.

    For end customers, the VARTA® Battery Search is an ideal tool to find the right battery.

    Go to VARTA® Battery Finder

  • With the wide range of starter batteries with various technologies and power classes, the choice is often difficult.

    For reliable engine cranks a sufficient CCA performance is crucial. For a long service life and best peace of mind, the battery technology (AGM, EFB, SLI) must match with the vehicle's energy demands. For energy demanding applications, especially for hoteling functions in Long-haul trucks or Caravans the capacity in combination with the recommended Depth-of-Discharge is crucial.

    The VARTA® Partner Portal for our partner workshops and the VARTA® Battery Search for customers makes it easy to select the right battery.

    Go to VARTA® Battery Finder

  • Extending your battery's lifespan involves a few key practices:

    1. Disconnect cables: Always disconnect the negative terminal first to prevent short circuits, then disconnect the positive terminal.
    2. Check battery's state: For non-maintenance-free lead-acid batteries, visit a professional. For maintenance-free batteries, clean vent pipes and avoid checking electrolyte levels.
    3. Start charging: Keep the battery upright if removing from the car. Turn off electrical consumers before connecting the charger. Connect the red cable to positive terminal first, then the black cable to negative terminal.
    4. Stop charging: Switch off charger when fully charged. Disconnect cables starting with the red cable from positive terminal, then the black cable from negative terminal.

    For more information find our article "How to extend the life of your battery".