For Extra Power and Premium Performance.

You've got a highly equipped car? The VARTA® Silver Dynamic is the perfect choice for non-start-stop technology with the highest power needs. It offers supreme starting power (up to 15% higher than Blue) that will meet the toughest energy demands without compromise. Available in 11 models of varying capacity, CCA and size, the VARTA® Silver Dynamic is also recyclable and produced in an energy saving way. 

 

Why choose VARTA Dynamic SLI for today’s vehicles?

VARTA Dynamic SLI is specifically designed for vehicles with low to moderate energy demands. It delivers strong starting power, is maintenance-free, and offers a long service life – even under demanding everyday conditions. It’s the ideal solution for drivers who value quality, reliability, and hassle-free operation.

VARTA batteries meet the highest OE standards and are engineered with precision in Germany – for consistent performance and maximum dependability.

Silver Dynamic, Blue Dynamic & Black Dynamic now go by a new name – introducing Dynamic SLI

VARTA Dynamic SLI is the successor to the former Silver Dynamic, Blue Dynamic, and Black Dynamic product lines. It’s based on the same trusted technology, now unified under one name.

If you’ve previously used a Silver, Blue, or Black Dynamic battery, you can easily switch to Dynamic SLI. Technology and performance remain unchanged. Going forward, Dynamic SLI clearly represents batteries for vehicles without start-stop systems and with traditional energy requirements.

  • NEW
    DYNAMIC SLI 571013060
    DYNAMIC SLI 571013060
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    72 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    640 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    571013060
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    E9
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    278/175/175
    ZA-Code
    651-95-I
  • NEW
    DYNAMIC SLI 600044085
    DYNAMIC SLI 600044085
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    100 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    850 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    600044085
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    H3
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    353/175/190
    ZA-Code
    658-95-I
  • NEW
    DYNAMIC SLI 560601054
    DYNAMIC SLI 560601054
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    60 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    540 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    560601054
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    D48
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    232/173/225
    ZA-Code
  • NEW
    DYNAMIC SLI 560600054
    DYNAMIC SLI 560600054
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    60 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    540 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    560600054
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    D47
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    232/173/225
    ZA-Code
    649-95-I
  • NEW
    DYNAMIC SLI 580043063
    DYNAMIC SLI 580043063
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    80 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    650 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    580043063
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    F16
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    315/175/190
    ZA-Code
    668H-95-I
  • NEW
    DYNAMIC SLI 570412060
    DYNAMIC SLI 570412060
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    72 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    600 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    570412060
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    E13
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    278/175/190
    ZA-Code
  • NEW
    DYNAMIC SLI 580401060
    DYNAMIC SLI 580401060
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    80 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    600 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    580401060
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    G4
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    306/173/225
    ZA-Code
  • NEW
    DYNAMIC SLI 545603030
    DYNAMIC SLI 545603030
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    45 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    430 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    545603030
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    B34
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    238/129/227
    ZA-Code
    634-95-I
  • NEW
    DYNAMIC SLI 543016037
    DYNAMIC SLI 543016037
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    43 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    370 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    543016037
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    B18
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    207/175/175
    ZA-Code
    619-95-I
  • NEW
    DYNAMIC SLI 580400060
    DYNAMIC SLI 580400060
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    80 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    600 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    580400060
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    G5
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    306/173/225
    ZA-Code
  • NEW
    DYNAMIC SLI 574013068
    DYNAMIC SLI 574013068
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    74 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    680 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    574013068
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    E12
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    278/175/190
    ZA-Code
    657-95-I
  • NEW
    DYNAMIC SLI 560077055
    DYNAMIC SLI 560077055
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    60 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    550 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    560077055
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    D59
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    242/175/175
    ZA-Code
    629-95-I
  • NEW
    DYNAMIC SLI 562019052
    DYNAMIC SLI 562019052
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    62 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    540 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    562019052
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    D24
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    242/175/190
    ZA-Code
    646-95-I
  • NEW
    DYNAMIC SLI 590400075
    DYNAMIC SLI 590400075
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    90 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    750 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    590400075
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    G7
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    306/173/225
    ZA-Code
    650S-95-I
  • NEW
    DYNAMIC SLI 545602030
    DYNAMIC SLI 545602030
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    45 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    340 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    545602030
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    B32
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    238/129/227
    ZA-Code
    636-95-I
  • NEW
    DYNAMIC SLI 540600034
    DYNAMIC SLI 540600034
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    40 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    340 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    540600034
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    A14
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    187/127/227
    ZA-Code
    616-95-I
  • NEW
    DYNAMIC SLI 590401075
    DYNAMIC SLI 590401075
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    90 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    750 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    590401075
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    G8
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    306/173/225
    ZA-Code
    650-95-I
  • NEW
    DYNAMIC SLI 610042090
    DYNAMIC SLI 610042090
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    110 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    900 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    610042090
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    I1
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    394/175/190
    ZA-Code
  • NEW
    DYNAMIC SLI 562021052
    DYNAMIC SLI 562021052
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    62 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    540 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    562021052
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    D43
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    242/175/190
    ZA-Code
  • NEW
    DYNAMIC SLI 550601040
    DYNAMIC SLI 550601040
    Capacity
    The amount of energy a vehicle battery can store is measured in Amp hours (Ah).
    50 Ah
    CCA
    A vehicle battery´s ability to start an engine in cold temperatures is measured in Cold Cranking Amps (CCA).
    400 A
    ETN
    The ETN number is a combination of the DIN numbering system which facilitates the changeover and gives further technical details about the battery model.
    550601040
    Short Code
    This code helps professionals quickly identify the correct battery for a specific application without having to rely solely on the battery´s full technical specifications.
    E20
    Voltage
    Voltage is the electrical force that powers the flow of current in a circuit, measured in volts.
    12 V
    Dimensions (L/W/H)
    The dimensions are in millimetres (mm).
    261/175/220
    ZA-Code

Trust a battery expert near you!

As cars become more and more complex so do their battery exchanges. That's why we do not recommend you to exchange your battery by yourself unless you are a battery professional. Instead, reach out to one of our trusted VARTA® Partner workshops instead

Got a question?

  • Since the turn of the millennium, start-stop technology has been introduced in more and more vehicle segments and models to comply with increasingly stringent emission regulations. Nowadays, there are hardly any new vehicles that are delivered without a start-stop function. In other words, the newer the vehicle, the more likely it is to feature automated engine shutoff.

    If the car is equipped with a Battery Management Sensor, it has a Start-Stop system or at least a Smart-Charging System that requires advanced battery technology such as AGM or EFB

    Go to VARTA® Battery Finder

  • For a car with a start-stop system, the recommended battery types are Absorbent Glass Mat (AGM) or an Enhanced Flooded Battery (EFB) battery.

    If an AGM battery is already installed in the vehicle, it must always be replaced with another AGM battery since the vehicle's Energy Management could overstress a Flooded battery which leads to shortend battery lifetime.

    Read Article

  • Although both AGM and EFB technologies are used for Start-Stop applications, there are some differences in the technologies' performance. While EFB is an improved flooded battery, AGM is a battery specifically designed for demanding applications and able to support any types of Start-Stop systems and even xEV.

    Downgrading from an AGM to an EFB is not recommended since the vehicle's Energy Management System is designed for a certain battery performance. Upgrading from EFB to AGM on the other hand, is always possible and advised when your customer faces recurring battery issues.

    Find more on AGM, EFB, xEV and more in our Knowledge section.

    Go to Knowledge